CAS OpenIR  > 中科院上海应用物理研究所2011-2019年
Preparation of a Novel Microcantilever Array Biochemical Sensor
Wu, L; Zhou, XR; Wu, SQ; Wang, P(王萍); Zhang, QC; Wu, XP
2012
Source PublicationCHINESE JOURNAL OF ANALYTICAL CHEMISTRY
ISSN0253-3820
Volume40Issue:4
AbstractTo eliminate the impact of environmental noise such as temperature drift and change of liquid refractive index in the single microcantilever biochemical sensing system and achieve rapid parallel detection of various of target molecules, a novel microcantilever array biochemical sensor was designed and constructed. When the microcantilever array is scanned by a piezoelectric-driven laser beam, the kinetic curves of the specific biochemical reaction on the microcantilever array surface is obtained by real-time monitoring the deflections of the microcantilevers with the optical lever read-out technique. In the experiment, the system optical stability was verified by 9 h scan of two fixed points with 250 mu m pitch, and also the system detection reliability was verified by the temperature excitation test, in which the microcantilever array deflections were basically consistent with each other (error 6.5%) when heating up 6 degrees C. Finally, we detected 10 mu g L-1 of clenbuterol antigen by immobilizing clenbuterol antibody on the gold-coated side of the microcantilever array with the self-made capillary array modification device, which verified the practical feasibility of the microcantilever array sensor.
Language英语
Funding Project应物所项目组
WOS IDWOS:000302781700001
Citation statistics
Cited Times:2[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/13252
Collection中科院上海应用物理研究所2011-2019年
Recommended Citation
GB/T 7714
Wu, L,Zhou, XR,Wu, SQ,et al. Preparation of a Novel Microcantilever Array Biochemical Sensor[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2012,40(4).
APA Wu, L,Zhou, XR,Wu, SQ,Wang, P,Zhang, QC,&Wu, XP.(2012).Preparation of a Novel Microcantilever Array Biochemical Sensor.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,40(4).
MLA Wu, L,et al."Preparation of a Novel Microcantilever Array Biochemical Sensor".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 40.4(2012).
Files in This Item: Download All
File Name/Size DocType Version Access License
Preparation of a Nov(338KB) 开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Wu, L]'s Articles
[Zhou, XR]'s Articles
[Wu, SQ]'s Articles
Baidu academic
Similar articles in Baidu academic
[Wu, L]'s Articles
[Zhou, XR]'s Articles
[Wu, SQ]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Wu, L]'s Articles
[Zhou, XR]'s Articles
[Wu, SQ]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Preparation of a Novel Microcantilever Array Biochemical Sensor.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.