CAS OpenIR  > 中科院上海应用物理研究所2011-2019年
Subpicosecond beam length measurement study based on the TM010 mode
Chen, Zhichu; Zhou, Weimin; Leng, Yongbin; Yu, Luyang; Yuan, Renxian
2013
Source PublicationPHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS
ISSN1098-4402
Volume16Issue:7
AbstractThis article discusses a beam length measurement technique based on the TM010 modes of two cavities in frequency domain. Since the TM010 pickup monitor has a much better signal-to-noise ratio (SNR) than the other monitors, it can improve the measuring range and resolution limit of the beam length measurement in the frequency domain to achieve the real-time measurement of the pulse duration of the order of 1 ps or less with the resolution of about 10 fs. The root-mean-square length of a beam-which does not necessarily have a Gaussian distribution-can be obtained by choosing the working frequency of the cavity to be much less than the critical frequency of the beam. The modeling and analysis of the above theory were also made simultaneously. The resulting resolution was about 100 fs when the step size was chosen to be 200 fs in this simulation after the higher order mode coupling effect was eliminated and the beam offset was corrected by using the Bessel function. An efficient algorithm was also provided in case the measurement system would achieve the SNR of 112 dB when there could be some issue in signal processing. This algorithm can still provide the length result with the resolution of 3.5 mu m for a beam duration of 0.1 ps when the SNR of the difference signal is as low as 10 dB.
Indexed BySCI
Language英语
Funding Project应物所项目组
WOS IDWOS:000321127500001
Citation statistics
Cited Times:2[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/13933
Collection中科院上海应用物理研究所2011-2019年
Recommended Citation
GB/T 7714
Chen, Zhichu,Zhou, Weimin,Leng, Yongbin,et al. Subpicosecond beam length measurement study based on the TM010 mode[J]. PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS,2013,16(7).
APA Chen, Zhichu,Zhou, Weimin,Leng, Yongbin,Yu, Luyang,&Yuan, Renxian.(2013).Subpicosecond beam length measurement study based on the TM010 mode.PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS,16(7).
MLA Chen, Zhichu,et al."Subpicosecond beam length measurement study based on the TM010 mode".PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS 16.7(2013).
Files in This Item:
File Name/Size DocType Version Access License
Subpicosecond beam l(541KB) 开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Chen, Zhichu]'s Articles
[Zhou, Weimin]'s Articles
[Leng, Yongbin]'s Articles
Baidu academic
Similar articles in Baidu academic
[Chen, Zhichu]'s Articles
[Zhou, Weimin]'s Articles
[Leng, Yongbin]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Chen, Zhichu]'s Articles
[Zhou, Weimin]'s Articles
[Leng, Yongbin]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Subpicosecond beam length measurement study based on the TM010 mode.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.