CAS OpenIR  > 中科院上海应用物理研究所2011-2019年
Performance of the infrared microspectroscopy station at SSRF
Zhang, ZY; Chen, M; Tong, YJ; Ji, T; Zhu, HC; Peng, WW; Zhang, M; Li, YJ; Xiao, TQ; chenmin@sinap.ac.cn
2014
Source PublicationINFRARED PHYSICS & TECHNOLOGY
ISSN1350-4495
Volume67Pages:521—525
AbstractAt the third generation synchrotron light source Shanghai Synchrotron Radiation Facility (SSRF), the first infrared beamline BL01B has been successfully constructed. The infrared beamline collects both bending magnet and edge radiation. A brief introduction of the infrared beamline design has been given in this article. The infrared microspectroscopy station is equipped with a Nicolet 6700 FTIR spectrometer and a Nicolet Continuum Microscope. The flux at the entrance of the FTIR spectrometer, the intensity profile, the signal to noise ratio (SNR) with different apertures, and the focused spot size of the infrared microspectroscopy station have been measured. The performances with synchrotron radiation infrared source and internal globar source have been compared. The results indicate that the infrared microspectroscopy station at SSRF has the ability of analysis samples in a small area with diffraction limited spatial resolution. (C) 2014 Elsevier B.V. All rights reserved.
KeywordCanadian Light-source Synchrotron-radiation Resolution Limits Beamline Spectromicroscopy Spectroscopy Facility Cells
Indexed BySCI
Language英语
WOS IDWOS:000346549700077
Citation statistics
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/14303
Collection中科院上海应用物理研究所2011-2019年
Corresponding Authorchenmin@sinap.ac.cn
Recommended Citation
GB/T 7714
Zhang, ZY,Chen, M,Tong, YJ,et al. Performance of the infrared microspectroscopy station at SSRF[J]. INFRARED PHYSICS & TECHNOLOGY,2014,67:521—525.
APA Zhang, ZY.,Chen, M.,Tong, YJ.,Ji, T.,Zhu, HC.,...&chenmin@sinap.ac.cn.(2014).Performance of the infrared microspectroscopy station at SSRF.INFRARED PHYSICS & TECHNOLOGY,67,521—525.
MLA Zhang, ZY,et al."Performance of the infrared microspectroscopy station at SSRF".INFRARED PHYSICS & TECHNOLOGY 67(2014):521—525.
Files in This Item: Download All
File Name/Size DocType Version Access License
Performance of the i(221KB) 开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zhang, ZY]'s Articles
[Chen, M]'s Articles
[Tong, YJ]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zhang, ZY]'s Articles
[Chen, M]'s Articles
[Tong, YJ]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zhang, ZY]'s Articles
[Chen, M]'s Articles
[Tong, YJ]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Performance of the infrared microspectroscopy station at SSRF.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.