CAS OpenIR  > 中科院上海应用物理研究所2011-2019年
X-ray fluorescence computed tomography with absorption correction for biomedical samples
Yang, Q; Deng, B; Du, GH; Xie, HL; Zhou, GZ; Xiao, TQ; Xu, HJ; dengbiao@sinap.ac.cn; tqxiao@sinap.ac.cn
2014
Source PublicationX-RAY SPECTROMETRY
ISSN0049-8246
Volume43Issue:5Pages:278—285
AbstractTo obtain accurate distributions of trace elements in biomedical samples nondestructively, the problems on absorption correction and radiation dose are confronted in X-ray fluorescence computed tomography. In this paper, the absorption-corrected ordered subsets expectation maximization (AC-OSEM) algorithm is developed to solve these problems. Simulation results show that the AC-OSEM-based X-ray fluorescence computed tomography is accurate when only the incident X-ray attenuation map is known and relatively fewer projections are provided. In addition, for the biomedical samples, the simplified approximate expression of the fluorescence attenuation map is practicable. Experiments on the biomedical samples were also carried out to evaluate the applicability of the AC-OSEM algorithm to soft tissues, which demonstrates that the distribution of the trace element Fe in the pathological liver could be clearly revealed. Copyright (C) 2014 John Wiley & Sons, Ltd.
KeywordElemental Microanalysis Image-reconstruction Ordered-subsets Xrf
Indexed BySCI
Language英语
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/14566
Collection中科院上海应用物理研究所2011-2019年
Corresponding Authordengbiao@sinap.ac.cn; tqxiao@sinap.ac.cn
Recommended Citation
GB/T 7714
Yang, Q,Deng, B,Du, GH,et al. X-ray fluorescence computed tomography with absorption correction for biomedical samples[J]. X-RAY SPECTROMETRY,2014,43(5):278—285.
APA Yang, Q.,Deng, B.,Du, GH.,Xie, HL.,Zhou, GZ.,...&tqxiao@sinap.ac.cn.(2014).X-ray fluorescence computed tomography with absorption correction for biomedical samples.X-RAY SPECTROMETRY,43(5),278—285.
MLA Yang, Q,et al."X-ray fluorescence computed tomography with absorption correction for biomedical samples".X-RAY SPECTROMETRY 43.5(2014):278—285.
Files in This Item:
File Name/Size DocType Version Access License
X-ray fluorescence c(3337KB) 开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yang, Q]'s Articles
[Deng, B]'s Articles
[Du, GH]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yang, Q]'s Articles
[Deng, B]'s Articles
[Du, GH]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yang, Q]'s Articles
[Deng, B]'s Articles
[Du, GH]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: X-ray fluorescence computed tomography with absorption correction for biomedical samples.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.