A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses
Longo, M; Rigon, L; Lopez, FCM; Chen, RC; Dreossi, D; Zanconati, F; Longo, R
2015
Source PublicationPHYSICS IN MEDICINE AND BIOLOGY
Volume60Issue:3Pages:N21—N34
Subtype期刊文献
AbstractThis work presents the first study of x-ray phase contrast imaging based on a simple implementation of the edge illumination method (EIXPCi) in the field of mammography with synchrotron radiation. A simplified EIXPCi set-up was utilized to study a possible application in mammography at clinical doses. Moreover, through a novel algorithm capable of separating and quantifying absorption and phase perturbations of images acquired in EIXPCi modality, it is possible to extract quantitative information on breast images, allowing an accurate tissue identification. The study was carried out at the SYRMEP beamline of Elettra synchrotron radiation facility (Trieste, Italy), where a mastectomy specimen was investigated with the EIXPCi technique. The sample was exposed at three different energies suitable for mammography with synchrotron radiation in order to test the validity of the novel algorithm in extracting values of linear attenuation coefficients integrated over the sample thickness. It is demonstrated that the quantitative data are in good agreement with the theoretical values of linear attenuation coefficients calculated on the hypothesis of the breast with a given composition. The results are promising and encourage the current efforts to apply the method in mammography with synchrotron radiation.
KeywordImaging Technique Ray Tomography
Indexed BySCI
Language英语
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/24386
Collection中科院上海应用物理研究所2011-2019年
Recommended Citation
GB/T 7714
Longo, M,Rigon, L,Lopez, FCM,et al. A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses[J]. PHYSICS IN MEDICINE AND BIOLOGY,2015,60(3):N21—N34.
APA Longo, M.,Rigon, L.,Lopez, FCM.,Chen, RC.,Dreossi, D.,...&Longo, R.(2015).A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses.PHYSICS IN MEDICINE AND BIOLOGY,60(3),N21—N34.
MLA Longo, M,et al."A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses".PHYSICS IN MEDICINE AND BIOLOGY 60.3(2015):N21—N34.
Files in This Item: Download All
File Name/Size DocType Version Access License
A simplified edge il(842KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Longo, M]'s Articles
[Rigon, L]'s Articles
[Lopez, FCM]'s Articles
Baidu academic
Similar articles in Baidu academic
[Longo, M]'s Articles
[Rigon, L]'s Articles
[Lopez, FCM]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Longo, M]'s Articles
[Rigon, L]'s Articles
[Lopez, FCM]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.