Alignment calibration and performance study of the STAR PXL detector
Ma, L; Dong, X; Qiu, H; Margetis, S; Ma, YG
2017
发表期刊NUCLEAR SCIENCE AND TECHNIQUES
ISSN1001-8042
卷号28期号:2页码:-
文章类型期刊论文
摘要We report in this paper the alignment calibration of the STAR pixel detector (PXL) prototype for the RHIC 2013 run and performance study of the full PXL detector installed and commissioned in the RHIC 2014 run. PXL detector is the innermost two silicon layers of the STAR heavy flavor tracker aiming at high-precision reconstruction of secondary decay vertex of heavy flavor particles. To achieve the physics goals, the calibration work was done on the detector with high precision. A histogram-based method was successfully applied for the alignment calibration, and the detector efficiency after alignment was studied using both p + p collision data and cosmic ray data.
关键词Alignment Calibration Heavy Flavor Tracker Star
DOI10.1007/s41365-016-0177-4
收录类别SCI
语种英语
WOS记录号WOS:000396183300011
引用统计
文献类型期刊论文
条目标识符http://ir.sinap.ac.cn/handle/331007/27250
专题中科院上海应用物理研究所2011-2018年
推荐引用方式
GB/T 7714
Ma, L,Dong, X,Qiu, H,et al. Alignment calibration and performance study of the STAR PXL detector[J]. NUCLEAR SCIENCE AND TECHNIQUES,2017,28(2):-.
APA Ma, L,Dong, X,Qiu, H,Margetis, S,&Ma, YG.(2017).Alignment calibration and performance study of the STAR PXL detector.NUCLEAR SCIENCE AND TECHNIQUES,28(2),-.
MLA Ma, L,et al."Alignment calibration and performance study of the STAR PXL detector".NUCLEAR SCIENCE AND TECHNIQUES 28.2(2017):-.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Alignment calibratio(2014KB)期刊论文作者接受稿开放获取CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Ma, L]的文章
[Dong, X]的文章
[Qiu, H]的文章
百度学术
百度学术中相似的文章
[Ma, L]的文章
[Dong, X]的文章
[Qiu, H]的文章
必应学术
必应学术中相似的文章
[Ma, L]的文章
[Dong, X]的文章
[Qiu, H]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。