CAS OpenIR  > 中科院上海应用物理研究所2011-2018年
Performance on absolute scattering intensity calibration and protein molecular weight determination at BL16B1, a dedicated SAXS beamline at SSRF
Zeng, JR; Bian, FG; Wang, J; Li, XH; Wang, YZ; Tian, F; Zhou, P
2017
Source PublicationJOURNAL OF SYNCHROTRON RADIATION
ISSN1600-5775
Volume24Pages:509-520
Subtype期刊论文
AbstractThe optical system and end-station of bending-magnet beamline BL16B1, dedicated to small-angle X-ray scattering (SAXS) at the Shanghai Synchrotron Radiation Facility, is described. Constructed in 2009 and upgraded in 2013, this beamline has been open to users since May 2009 and supports methodologies including SAXS, wide-angle X-ray scattering (WAXS), simultaneous SAXS/WAXS, grazing-incidence small-angle X-ray scattering (GISAXS) and anomalous small-angle X-ray scattering (ASAXS). Considering that an increasing necessity for absolute calibration of SAXS intensity has been recognized in in-depth investigations, SAXS intensity is re-stated according to the extent of data processing, and the absolute intensity is suggested to be a unified presentation of SAXS data in this article. Theory with a practical procedure for absolute intensity calibration is established based on BL16B1, using glass carbon and water as primary and secondary standards, respectively. The calibration procedure can be completed in minutes and shows good reliability under different conditions. An empirical line of scale factor estimation is also established for any specific SAXS setup at the beamline. Beamline performance on molecular weight (MW) determination is provided as a straightforward application and verification of the absolute intensity calibration. Results show good accuracy with a deviation of less than 10% compared with the known value, which is also the best attainable accuracy in recent studies using SAXS to measure protein MW. Fast MW measurement following the demonstrated method also enables an instant check or pre-diagnosis of the SAXS performance to improve the data acquisition.
KeywordBeamline Saxs Absolute Intensity Calibration Molecular Weight
DOI10.1107/S1600577516019135
Indexed BySCI
Language英语
WOS IDWOS:000395093600019
Citation statistics
Cited Times:22[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/27409
Collection中科院上海应用物理研究所2011-2018年
Recommended Citation
GB/T 7714
Zeng, JR,Bian, FG,Wang, J,et al. Performance on absolute scattering intensity calibration and protein molecular weight determination at BL16B1, a dedicated SAXS beamline at SSRF[J]. JOURNAL OF SYNCHROTRON RADIATION,2017,24:509-520.
APA Zeng, JR.,Bian, FG.,Wang, J.,Li, XH.,Wang, YZ.,...&Zhou, P.(2017).Performance on absolute scattering intensity calibration and protein molecular weight determination at BL16B1, a dedicated SAXS beamline at SSRF.JOURNAL OF SYNCHROTRON RADIATION,24,509-520.
MLA Zeng, JR,et al."Performance on absolute scattering intensity calibration and protein molecular weight determination at BL16B1, a dedicated SAXS beamline at SSRF".JOURNAL OF SYNCHROTRON RADIATION 24(2017):509-520.
Files in This Item: Download All
File Name/Size DocType Version Access License
Performance on absol(1322KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zeng, JR]'s Articles
[Bian, FG]'s Articles
[Wang, J]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zeng, JR]'s Articles
[Bian, FG]'s Articles
[Wang, J]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zeng, JR]'s Articles
[Bian, FG]'s Articles
[Wang, J]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Performance on absolute scattering intensity calibration and protein molecular weight determination at BL16B1, a dedicated SAXS beamline at SSRF.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.