CAS OpenIR  > 中科院上海应用物理研究所2011-2019年
The CUORE cryostat and its bolometric detector
Santone, D; Alduino, C; Alfonso, K; Artusa, DR; Avignone, FT; Azzolini, O; Banks, TI; Bari, G; Beeman, JW; Bellini, F; Bersani, A; Biassoni, M; Branca, A; Brofferio, C; Bucci, C; Camacho, A; Caminata, A; Canonica, L; Cao, XG; Capelli, S; Cappelli, L; Carbone, L; Cardani, L; Carniti, P; Casali, N; Cassina, L; Chiesa, D; Chott, N; Clemenza, M; Copello, S; Cosmelli, C; Cremonesi, O; Creswick, RJ; Cushman, JS; D'Addabbo, A; Dafinei, I; Davis, CJ; Dell'Oro, S; Deninno, MM; Di Domizio, S; Di Vacri, ML; Drobizhev, A; Fang, DQ; Faverzani, M; Fernandes, G; Ferri, E; Ferroni, F; Fiorini, E; Franceschi, MA; Freedman, SJ; Fujikawa, BK; Giachero, A; Gironi, L; Giuliani, A; Gladstone, L; Gorla, P; Gotti, C; Gutierrez, TD; Haller, EE; Han, K; Hansen, E; Heeger, KM; Hennings-Yeomans, R; Hickerson, KP; Huang, HZ; Kadel, R; Keppel, G; Kolomensky, YG; Leder, A; Ligi, C; Lim, KE; Liu, X; Ma, YG; Maino, M; Marini, L; Martinez, M; Maruyama, RH; Mei, Y; Moggi, N; Morganti, S; Mosteiro, PJ; Napolitano, T; Nones, C; Norman, EB; Novati, V; Nucciotti, A; O'Donnell, T; Orio, F; Ouellet, JL; Pagliarone, CE; Pallavicini, M; Palmieri, V; Pattavina, L; Pavan, M; Pessina, G; Pettinacci, V; Piperno, G; Pira, C; Pirro, S; Pozzi, S; Previtali, E; Rosenfeld, C; Rusconi, C; Sangiorgio, S; Scielzo, ND; Singh, V; Sisti, M; Smith, AR; Taffarello, L; Tenconi, M; Terranova, F; Tomei, C; Trentalange, S; Vignati, M; Wagaarachchi, SL; Wang, BS; Wang, HW; Wilson, J; Winslow, LA; Wise, T; Woodcraft, A; Zanotti, L; Zhang, GQ; Zhu, BX; Zimmermann, S; Zucchelli, S
2017
Source PublicationJOURNAL OF INSTRUMENTATION
ISSN1748-0221
Volume12Pages:-
Subtype期刊论文
AbstractCUORE is a cryogenic detector that will be operated at LNGS to search for neutrinoless double beta decay (0 nu beta beta) of Te-130. The detector installation was completed in summer 2016. Before the installation, several cold runs were done to test the cryogenic system performance. In the last cold run the base temperature of 6.3mK was reached in stable condition. CUORE-0, a CUORE prototype, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach.
KeywordCalorimeters Cryogenic Detectors Cryogenics And Thermal Models Double-beta Decay Detectors
DOI10.1088/1748-0221/12/02/C02055
Indexed BySCI
Language英语
WOS IDWOS:000397825800054
Citation statistics
Cited Times:1[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/27470
Collection中科院上海应用物理研究所2011-2019年
Recommended Citation
GB/T 7714
Santone, D,Alduino, C,Alfonso, K,et al. The CUORE cryostat and its bolometric detector[J]. JOURNAL OF INSTRUMENTATION,2017,12:-.
APA Santone, D.,Alduino, C.,Alfonso, K.,Artusa, DR.,Avignone, FT.,...&Zucchelli, S.(2017).The CUORE cryostat and its bolometric detector.JOURNAL OF INSTRUMENTATION,12,-.
MLA Santone, D,et al."The CUORE cryostat and its bolometric detector".JOURNAL OF INSTRUMENTATION 12(2017):-.
Files in This Item:
File Name/Size DocType Version Access License
The CUORE cryostat a(3136KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Santone, D]'s Articles
[Alduino, C]'s Articles
[Alfonso, K]'s Articles
Baidu academic
Similar articles in Baidu academic
[Santone, D]'s Articles
[Alduino, C]'s Articles
[Alfonso, K]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Santone, D]'s Articles
[Alduino, C]'s Articles
[Alfonso, K]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: The CUORE cryostat and its bolometric detector.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.