CAS OpenIR  > 中科院上海应用物理研究所2011-2018年
A new consecutive energy calibration method for X/gamma detectors based on energy continuously tunable laser Compton scattering light source
Xu, HH; Wu, HL; Fan, GT; Chen, JH; Wang, D
2017
Source PublicationNUCLEAR SCIENCE AND TECHNIQUES
ISSN1001-8042
Volume28Issue:9Pages:-
Subtype期刊论文
AbstractIn this paper, we present an energy calibration method based on steep Compton edges of the laser Compton scattered (LCS) photon energy spectra. It performs consecutive energy calibration in the neighborhood of certain energy, hence improves calibration precision in the energy region. It can also achieve direct calibration at high energy region (several MeV) where detectors can only be calibrated by extrapolation in conventional methods. These make it suitable for detectors that need wide-range energy calibration with high precision. The effects of systematic uncertainties on accuracy of this calibration method are studied by simulation, using the design parameters of a LCS device-SINAP III. The results show that the SINAP III device is able to perform energy calibration work over the energy region of 25-740 keV. The precision of calibration is better than 1.6% from 25 to 300 keV and is better than 0.5% from 300 to 740 keV.
KeywordElectron Storage-ring Gamma-ray X-ray Synchrotron-radiation Beam Backscattering Facility Photons Inverse
DOI10.1007/s41365-017-0272-1
WOS KeywordELECTRON STORAGE-RING ; GAMMA-RAY ; X-RAY ; SYNCHROTRON-RADIATION ; BEAM ; BACKSCATTERING ; FACILITY ; PHOTONS ; INVERSE
Indexed BySCI
Language英语
WOS IDWOS:000408853800002
Citation statistics
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/28543
Collection中科院上海应用物理研究所2011-2018年
Recommended Citation
GB/T 7714
Xu, HH,Wu, HL,Fan, GT,et al. A new consecutive energy calibration method for X/gamma detectors based on energy continuously tunable laser Compton scattering light source[J]. NUCLEAR SCIENCE AND TECHNIQUES,2017,28(9):-.
APA Xu, HH,Wu, HL,Fan, GT,Chen, JH,&Wang, D.(2017).A new consecutive energy calibration method for X/gamma detectors based on energy continuously tunable laser Compton scattering light source.NUCLEAR SCIENCE AND TECHNIQUES,28(9),-.
MLA Xu, HH,et al."A new consecutive energy calibration method for X/gamma detectors based on energy continuously tunable laser Compton scattering light source".NUCLEAR SCIENCE AND TECHNIQUES 28.9(2017):-.
Files in This Item:
File Name/Size DocType Version Access License
A new consecutive en(1126KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Xu, HH]'s Articles
[Wu, HL]'s Articles
[Fan, GT]'s Articles
Baidu academic
Similar articles in Baidu academic
[Xu, HH]'s Articles
[Wu, HL]'s Articles
[Fan, GT]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Xu, HH]'s Articles
[Wu, HL]'s Articles
[Fan, GT]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: A new consecutive energy calibration method for X_gamma detectors based on energy continuously tunable laser Compton scattering light source.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.