Improving the efficiency of small-angle x-ray scattering computed tomography using the OSEM algorithm
Hu, T; Wang, YD; Du, GH; Wang, YZ; Hua, WQ; Deng, BA; Xie, HL; Bian, FG; Xiao, TQ
2017
Source PublicationAPPLIED OPTICS
ISSN1559-128X
Volume56Issue:30Pages:8326-8334
Subtype期刊论文
AbstractSmall-angle x-ray scattering computed tomography (SAXS-CT) is a nondestructive method for the nanostructure analysis of heterogeneous materials. However, the limits of a long data acquisition time and vast amounts of data prevent SAXS-CT from becoming a routine experimental method in the applications of synchrotron radiation. In this study, the ordered subsets expectation maximization (OSEM) algorithm is introduced to improve the efficiency of SAXS-CT. To demonstrate the practicability of this method, a systematic simulation and experiments were carried out. The simulation results on a numerical phantom show that the OSEM-based SAXS-CT can effectively eliminate streaking artifacts and improve the efficiency of data acquisition by at least 3 times compared with the filter backprojection algorithm. By compromising the reconstruction speed and image quality, the optimal reconstruction parameters are also given for the image reconstruction in the OSEM-based SAXS-CT experiments. An experiment on a bamboo sample verified the validity of the proposed method with limited projection data. A further experiment on polyethylene demonstrated that the OSEM-based SAXS-CT is able to reveal the local nanoscale information about the crystalline structure and distributional difference inside the sample. In conclusion, the OSEM-based SAXS-CT can significantly improve experimental efficiency, which may promote SAXS-CT becoming a conventional method. (C) 2017 Optical Society of America
KeywordOrdered-subsets Image-reconstruction Bone Nanostructure Brain Ct
DOI10.1364/AO.56.008326
WOS KeywordORDERED-SUBSETS ; IMAGE-RECONSTRUCTION ; BONE ; NANOSTRUCTURE ; BRAIN ; CT
Indexed BySCI
Language英语
WOS IDWOS:000413345300004
Citation statistics
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/28690
Collection中科院上海应用物理研究所2011-2018年
Recommended Citation
GB/T 7714
Hu, T,Wang, YD,Du, GH,et al. Improving the efficiency of small-angle x-ray scattering computed tomography using the OSEM algorithm[J]. APPLIED OPTICS,2017,56(30):8326-8334.
APA Hu, T.,Wang, YD.,Du, GH.,Wang, YZ.,Hua, WQ.,...&Xiao, TQ.(2017).Improving the efficiency of small-angle x-ray scattering computed tomography using the OSEM algorithm.APPLIED OPTICS,56(30),8326-8334.
MLA Hu, T,et al."Improving the efficiency of small-angle x-ray scattering computed tomography using the OSEM algorithm".APPLIED OPTICS 56.30(2017):8326-8334.
Files in This Item: Download All
File Name/Size DocType Version Access License
Improving the effici(1904KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Hu, T]'s Articles
[Wang, YD]'s Articles
[Du, GH]'s Articles
Baidu academic
Similar articles in Baidu academic
[Hu, T]'s Articles
[Wang, YD]'s Articles
[Du, GH]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Hu, T]'s Articles
[Wang, YD]'s Articles
[Du, GH]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Improving the efficiency of small-angle x-ray scattering computed tomography using the OSEM algorithm.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.