CAS OpenIR  > 中科院上海应用物理研究所2011-2018年
New design for multi-crystal data collection at SSRF
Li, B; Huang, S; Pan, QY; Li, MJ; Zhou, H; Wang, QS; Yu, F; Sun, B; Chen, JQ; He, JH
2018
Source PublicationNUCLEAR SCIENCE AND TECHNIQUES
ISSN1001-8042
Volume29Issue:2Pages:-
Subtype期刊论文
AbstractData collection with microcrystals at synchrotron radiation facilities is challenging because it is difficult to harvest and locate microcrystals. Moreover, microcrystals are sensitive to radiation damage; thus, typically, a complete data set cannot be obtained with a single microcrystal. Herein, we report a new method for data collection with multiple microcrystals having a crystal size ranging from 1 to 30 mu m. This method is suitable for not only low-temperature (100 K) data collection but also room-temperature data collection. Thin Kapton membranes were used to capture multiple crystals simultaneously. The microcrystals were visible under an optical microscope and easily located because the membrane was transparent and sufficiently thin. The film was fixed to a bracket that was prepared using a three-dimensional printer. The bracket was fixed on a magnetic base via screwing and employed by the goniometer system for data collection. Multiple data sets of fatty acid-binding protein 4 (FABP4) and lysozyme microcrystals were collected using this novel designed device. Finally, the structures of protein FABP4 and lysozyme were obtained from these data via the molecule replacement method. The data statistics reveal that this method provides a comparable result to traditional methods such as a nylon loop.
KeywordMembrane-proteins Crystallography Radiation Chip
DOI10.1007/s41365-018-0357-5
Indexed BySCI
Language英语
WOS IDWOS:000427326900005
Citation statistics
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/29084
Collection中科院上海应用物理研究所2011-2018年
Affiliation1.Li, B
2.Huang, S
3.Pan, QY
4.Li, MJ
5.Zhou, H
6.Wang, QS
7.Yu, F
8.Sun, B
9.Chen, JQ
10.He, JH
Recommended Citation
GB/T 7714
Li, B,Huang, S,Pan, QY,et al. New design for multi-crystal data collection at SSRF[J]. NUCLEAR SCIENCE AND TECHNIQUES,2018,29(2):-.
APA Li, B.,Huang, S.,Pan, QY.,Li, MJ.,Zhou, H.,...&He, JH.(2018).New design for multi-crystal data collection at SSRF.NUCLEAR SCIENCE AND TECHNIQUES,29(2),-.
MLA Li, B,et al."New design for multi-crystal data collection at SSRF".NUCLEAR SCIENCE AND TECHNIQUES 29.2(2018):-.
Files in This Item: Download All
File Name/Size DocType Version Access License
New design for multi(724KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Li, B]'s Articles
[Huang, S]'s Articles
[Pan, QY]'s Articles
Baidu academic
Similar articles in Baidu academic
[Li, B]'s Articles
[Huang, S]'s Articles
[Pan, QY]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Li, B]'s Articles
[Huang, S]'s Articles
[Pan, QY]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: New design for multi-crystal data collection at SSRF.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.