Ma, W; Abdukerim, A; Bo, Z; Chen, W; Chen, X; Chen, Y; Cheng, C; Cui, X; Fan, Y; Fang, D; Fu, C; Fu, M; Geng, L; Giboni, K; Gu, L; Guo, X; Han, K; He, C; He, S; Huang, D; Huang, Y; Huang, Z; Ji, X; Ju, Y; Li, S; Liu, H; Liu, J; Ma, Y; Mao, Y; Meng, Y; Ni, K; Ning, J; Ning, X; Ren, X; Shang, C; Si, L; Shen, G; Tan, A; Wang, A; Wang, H; Wang, M; Wang, Q; Wang, S; Wang, W; Wang, X; Wang, Z; Wu, M; Wu, S; Wu, W; Xia, J; Xiao, M; Xie, P; Yan, B; Yang, J; Yang, Y; Yu, C; Yuan, J; Yuan, Y; Yue, J; Zeng, X; Zhang, D; Zhang, T; Zhao, L; Zheng, Q; Zhou, J; Zhou, N; Zhou, X
2020
Source PublicationJOURNAL OF INSTRUMENTATION
ISSN1748-0221
Volume15Issue:12Pages:-
Subtype期刊论文
AbstractWe have developed a low-energy electron recoil (ER) calibration method with Rn-220 for the PandaX-II detector. Rn-220, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to alpha, beta, and gamma particles with focus on low energy ER events. During the runs in 2017 and 2018, the amount of radioactivity of Rn-222 were on the order of 1% of that of Rn-220 and thorium particulate contamination was negligible, especially in 2018. We also measured the background contribution from Pb-214 for the first time in PandaX-II with the help from a Rn-222 injection. Calibration strategy with Rn-220 and Rn-222 will be implemented in the upcoming PandaX-4T experiment and can be useful for other xenon-based detectors as well.
KeywordDARK-MATTER DETECTION
DOI10.1088/1748-0221/15/12/P12038
Indexed BySCI
Language英语
Citation statistics
Cited Times:3[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.sinap.ac.cn/handle/331007/32952
Collection中科院上海应用物理研究所2011-2020年
Affiliation1.Shanghai Jiao Tong Univ, INPAC, MOE Key Lab Particle Phys Astrophys & Cosmol, Shanghai Key Lab Particle Phys & Cosmol, Shanghai 200240, Peoples R China
2.Shanghai Jiao Tong Univ, Sch Phys & Astron, MOE Key Lab Particle Phys Astrophys & Cosmol, Shanghai Key Lab Particle Phys & Cosmol, Shanghai 200240, Peoples R China
3.Shanghai Jiao Tong Univ, Sichuan Res Inst, Chengdu 610213, Peoples R China
4.Yalong River Hydropower Dev Co Ltd, 288 Shuanglin Rd, Chengdu 610051, Peoples R China
5.Sun Yat Sen Univ, Sch Phys, Guangzhou 510275, Peoples R China
6.Shanghai Jiao Tong Univ, Tsung Dao Lee Inst, Shanghai 200240, Peoples R China
7.Nankai Univ, Sch Phys, Tianjin 300071, Peoples R China
8.Fudan Univ, Inst Modern Phys, Key Lab Nucl Phys & Ion Beam Applicat MOE, Shanghai 200433, Peoples R China
9.Peking Univ, Sch Phys, Beijing 100871, Peoples R China
10.Beihang Univ, Sch Phys, Beijing 100191, Peoples R China (1
11.Beihang Univ, Int Res Ctr Nuclei & Particles Cosmos, Beijing 100191, Peoples R China
12.Beihang Univ, Beijing Key Lab Adv Nucl Mat & Phys, Beijing 100191, Peoples R China
13.Univ Shanghai Sci & Technol, Sch Med Instrument & Food Engn, Shanghai 200093, Peoples R China
14.Univ Maryland, Dept Phys, College Pk, MD 20742 USA
15.Shanghai Jiao Tong Univ, Sch Mech Engn, Shanghai 200240, Peoples R China
16.Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
17.Shandong Univ, Sch Phys, Jinan 250100, Peoples R China
18.Shandong Univ, Key Lab Particle Phys & Particle Irradiat MOE, Jinan 250100, Peoples R China
19.Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China
20.Univ Chinese Acad Sci, Beijing 100049, Peoples R China (2
21.Peking Univ, Ctr High Energy Phys, Beijing 100871, Peoples R China
Recommended Citation
GB/T 7714
Ma, W,Abdukerim, A,Bo, Z,et al. Internal calibration of the PandaX-II detector with radon gaseous sources[J]. JOURNAL OF INSTRUMENTATION,2020,15(12):-.
APA Ma, W.,Abdukerim, A.,Bo, Z.,Chen, W.,Chen, X.,...&Zhou, X.(2020).Internal calibration of the PandaX-II detector with radon gaseous sources.JOURNAL OF INSTRUMENTATION,15(12),-.
MLA Ma, W,et al."Internal calibration of the PandaX-II detector with radon gaseous sources".JOURNAL OF INSTRUMENTATION 15.12(2020):-.
Files in This Item: Download All
File Name/Size DocType Version Access License
Internal calibration(3293KB)期刊论文出版稿开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Ma, W]'s Articles
[Abdukerim, A]'s Articles
[Bo, Z]'s Articles
Baidu academic
Similar articles in Baidu academic
[Ma, W]'s Articles
[Abdukerim, A]'s Articles
[Bo, Z]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Ma, W]'s Articles
[Abdukerim, A]'s Articles
[Bo, Z]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Internal calibration of the PandaX-II detector with radon gaseous sources.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.