Knowledge Management System Of Shanghai Institute of Applied Physics, CAS
Analysis and calculation on electron bunch length measurement by using CDR | |
Liu, AQ(刘爱琴); Liu, ZP(刘征平); Chen, YZ(陈永忠); Zhou, WM(周伟民); Dai, ZM(戴志敏); Liu, AQ (reprint author), Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China | |
2005 | |
Source Publication | HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION
![]() |
ISSN | 0254-3052 |
Volume | 29Issue:5Pages:517 |
Abstract | Measurement of electron bunch length through its generated coherent diffraction radiation (CDR) via optical autocorrelation is a new non-intercepting frequency domain diagnostics technique developed in accelerator fields recently. In this paper, the CDR emitted by femto-second electron bunches provided by the SINAP linac are analyzed and numerically calculated, experimental designs on CDR generation and bunch length measurement are presented, and the beam splitter affected interferogram is simulated. As a result, broad band continuous and high intensity CDR covering a range from far-infrared to mm-wave region can be obtained by directly using these bunches. CDR energy is mainly concentrated near the beam axis and can be up to several millijoules for Gaussian bunches. We use a far-infrared Michelson interferometer and a Golay detector to measure the autocorrelation interferogram of CDR, considering the interference effects caused by the beam splitter, the electron bunch length can be easily obtained, from which one can derive its electron density distribution. |
Keyword | Coherent Diffraction Radiation Bunch Length Diagnosis Femto-second Electron Bunches Optical Autocorrelation Far-infrared Michelson Interferometer |
Subject Area | Chemistry ; Physics |
Indexed By | sci |
Language | 英语 |
Funding Project | 应物所项目组 |
Document Type | 期刊论文 |
Identifier | http://ir.sinap.ac.cn/handle/331007/8011 |
Collection | 中科院上海应用物理研究所2004-2010年 |
Corresponding Author | Liu, AQ (reprint author), Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China |
Recommended Citation GB/T 7714 | Liu, AQ,Liu, ZP,Chen, YZ,et al. Analysis and calculation on electron bunch length measurement by using CDR[J]. HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,2005,29(5):517. |
APA | Liu, AQ,Liu, ZP,Chen, YZ,Zhou, WM,Dai, ZM,&Liu, AQ .(2005).Analysis and calculation on electron bunch length measurement by using CDR.HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,29(5),517. |
MLA | Liu, AQ,et al."Analysis and calculation on electron bunch length measurement by using CDR".HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION 29.5(2005):517. |